Foretravel offers several technical support options. Motorcade Club Members will have technical questions answered by phone on a first come first served basis. Non-Motorcade Club Members can submit technical questions via Email ONLY with a response as soon as possible. We do have a database of questions and answers that may be helpful in finding the answers to your questions. During normal business hours please feel to contact at the factory: 1.800.955.6226 (Option #3 - Technical Assistance) Monday - Friday, 7:30Am - 4Pm CST service.office@foretravel.com
Technical Q&A
Category: Component Mechanicals / Section: Engine
Available Topics
Have a 92 U300 with detroit 6v92. Has been sitting for 6 months. Motor starts but check engine light comes on in four seconds and auto shutdown occurs in 30 seconds later. Will start right up but repeats in 36 seconds. Oil level is good - Water topped off in radiator - Oil never reaches high temp. Fuel filter is new and no water comes out of drain. Large air filer is clean and coach still shuts down even if is removed. Where do I begin. When motor runs it seems fine and sounds great.
Answer
When the engine goes into shutdown it is usually one of three things in relation to what the engine computer is receiving from it’s various sensors. 1) High Temperature, 2) Low Oil Pressure or, 3) Low Coolant level. If all checks appear normal appear normal it may be that you will have to get a local Detroit mechanic to the coach or have towed to a shop to hook up a reader to the engine and determine cause.